Video Wall Solution

If 3 x 3 Video wall solution,

 

Saffron has Display port equalizing loop through function,

According to specifications of saffron is no limit to the additional screen.

For Setting cideo wall contiguration, Enter to “Public Display” menu

Inside sub menu of “Public Display”

 

  • X Number : The number of screens in Horizontal (see next page)
  • Y Number : The number of screens in Vertical (see next page)
  • Display Number : User defined physical screen # ID (see next page)
  • X Gap : Horizontal active area’s edge control option.
  • Y Gap : Vertical active area’s edge control option.
  • SET ID : Each device ID for RS-232 commands control
  • Enable : Multi Vision Enable/Disable option.

Saffron designed the specific screen location assignment as shown above

a) For 2×2 Multi Vision , refer to purple box

   – User define 1-1 screen, set OSD value as following.

   – X Number : 2  Y Number : 2

   – Display Number : 1

   – User define 1-2 screen, set OSD value as following.

   – X Number : 2  Y Number : 2

   – Display Number : 3

b) For 5×1 Multi Vision , refer to red box

   – User define 3-1 screen, set OSD value as following.

   – X Number : 5  Y Number : 1

   – Display Number : 3

C) For 4×4 Multi Vision , refer to black box

   – User define 4-1 screen, set OSD value as following.

   – X Number : 4  Y Number : 4

   – Display Number : 4

   – User define 1-3 screen, set OSD value as following.

  – X Number : 4  Y Number : 4

  – Display Number : 9

  – User define 3-4 screen, set OSD value as following.

  – X Number : 4  Y Number : 4

  – Display Number : 15

 

a) X Gap

The function for the fine adjustment of the display distortion caused by the distance between

   LCD bezel to bezel.

– Left/Right of picture cut value.

b) Y Gap

The function for the fine adjustment of the display distortion caused by the distance between

   LCD bezel to bezel.

– Top/Bottom of picture cut value,

 

 

-SET ID is specific ID for each screen, when user control remote access by RS-232 protocol.

-User should assign SED ID on OSD menu only for each screen.

Using “MultiVisionUart.exe” what ESTECOM designed console software.

-User can send all Video Wall parameters through console software.

When send a command to specific screen, need to select designated SET ID what you assigned by OSD menu.

 

-“Multi-Vision Show option for Video Wall contents programming.

Each Video Wall configuration, such as 2×2, 5×3… has own “ Scene” option as shown above.

For more detail, please contact to tech@estecom.co.kr